Base isolation of multi-storied building using lead rubber bearing

  • Al Amin Graduate Student, Department of Civil Engineering, University of Asia Pacific (UAP), Dhaka, Bangladesh http://orcid.org/0000-0001-6517-0105
  • Mufedul Islam Graduate Student, Department of Civil Engineering, University of Asia Pacific (UAP), Dhaka, Bangladesh http://orcid.org/0000-0003-3166-4574
  • Md. Jobaer Ahamed Graduate Student, Department of Civil Engineering, University of Asia Pacific (UAP), Dhaka, Bangladesh http://orcid.org/0000-0002-4448-1761

Abstract

Earthquake resistance building design is the most important thing to ensure safety and minimize loss in recent years. Nowadays, many techniques are being used in earthquake resistance building design. Base-isolation is one of the best techniques used in earthquake resistant design building in economical. It reduces seismic energy transmitted to buildings, in highly seismic prone areas. Lead Rubber Bearings are the most widely used technology in seismic base isolation, because of its technical and economic effectiveness and reliability. In this research, a multi-storied building that is located in Dhaka city is performed at numerically design as a base isolation building where the lead rubber bearing is designed and used as isolator. The building is analyzed for El Centro earthquake data of 15, 20, and 25 second. For base isolated and non-isolated condition nonlinear time history analysis is done using SAP2000 18. By comparing displacement vs time, acceleration vs time graphs for base isolated and non-isolated condition, the displacement difference between top and bottom floor is almost close that indicates this building structural behavior better during lateral load.

Downloads

Download data is not yet available.

References

Kelly, J. M., & Hodder, S. B. (1982). Experimental study of lead and elastomeric dampers for base isolation systems in laminated neoprene bearings. Bulletin of the New Zealand National Society for Earthquake Engineering, 15(2), 53-67.

Bachas, N., Duefias, L., Kelly, J. P. and Wu, T., "The Rehabilitation of Mitchell Hall for Seismic Upgrade", Master of Engineering 2001 project, Department of Civil and Environmental Engineering, Massachusetts Institution of Technology, 2001.

Jung, H. J., Eem, S. H., Jang, D. D., & Koo, J. H. (2011). Seismic performance analysis of a smart base-isolation system considering dynamics of MR elastomers. Journal of Intelligent Material Systems and Structures, 22(13), 1439-1450.

Zhao, G. F., & Ma, Y. H. (2011). Parameters study of rural buildings structures supported on slide-limited friction base isolation system. Zhendong yu Chongji(Journal of Vibration and Shock), 30(11), 148-152.

Kelly, J. M., & Hodder, S. B. (1982). Experimental study of lead and elastomeric dampers for base isolation systems in laminated neoprene bearings. Bulletin of the New Zealand National Society for Earthquake Engineering, 15(2), 53-67.

Sayed-Ahmed, M. (2012). Building with base isolation techniques. Journal of Al-Azhar University Engineering Sector (JAUES), 7(1), 147-159

International Conference of Building Officials. (1997). Uniform building code. International Conference of Building Officials.

Muhi, F.H., Mouli,D.C., Kumar, K.S., Babu, T,H., (2016). Comparative Behavior of Structure with and without Base Isolation Devices and Detailed Study on Retrofitting of Structures using SAP 2000. International Journal of Advanced Technology and Innovative Research, 08(04), 643-649.

Mayes, R. L., & Naeim, F. (2001). Design of structures with seismic isolation. In The seismic design handbook (pp. 723-755). Springer US.

Martelli, A. and Forni M. (2011a). Recent Worldwide Application of Seismic Isolation and Energy Dissipation and Conditions for Their Correct Use. Structural Engineering World Congress (SEW5), (6), 52-59.

Martelli, A. and Forni, M. (2011b). Seismic Retrofit of Existing Buildings by Means of Seismic Isolation: Some Remarks on the Italian Experience and the New Projects. COMPDYN 2011 Conference. Proceedings on CD.